AC short Circuit Current Limit Load Protection Module Relay 0.5A-20A

Description
The AC protection switch can independently cut off the short
circuit/current limiting protection module of the power supply line
(Test object: AC current, with real-time current detection,
protection current range: 0.5A-20A)
Electrical parameters of this module:
DC power supply voltage: 9-24VDC;
Power supply current: 100mA-200mA;
Working temperature: -20 degrees ~ 125 degrees;
Isolation voltage: 1.5KV;
Current limit current range: 0.5A-20A
(1) When the actual current exceeds the current set by us,
the relay can automatically disconnect the power supply line to protect the
load.
(The actual current can be converted to the corresponding
output voltage through the detection of the sensor, and then compared with the
reference voltage)
How to set the current:
(2)
The current setting of the board is adjusted by the
adjustable resistance on the board. (Highlights: This adjustable
resistance can be freely rotated manually)
Unlock button:
(3)
The board has a small button, which can be set to lock and
unlock.
Press the LOCK state: the relay is permanently locked;
It is in the Unlock state when it pops up: the relay will
operate when it is over-current, but not when it is flowing.
Board size:
(3) 56mm*55mm with 4 M3 fixed mounting holes.
Shipping list:
(1) One AC current limiting protection module;
(2) One 4-color cable;
(3) An electronic file instruction manual;
Benefits of this module:
(4) It comes with a relay, which automatically cuts off the power supply line after overcurrent, and has a fast response time;
it can be set
in two states, locked and unlocked, and the adjustable resistance can be
manually rotated
Applications:
1) AC/DC current detection;
2) Motor stall/heat protection;
3) Leakage protection;
4) Real-time sampling of load current A/D
Detection principle
u First connect the single wire of the test object in series to the seat J4 of the board. After fixing it,
we supply power to the small
board and also allow the testing equipment to start working normally. At
the same time, press the lock button in the LOCK state.
u At this time, we refer to the CH1_Work indicator on the
board. If the CH1_Work LED is off at this time, turn the adjustable resistor
R17 toward the (+) arrow (clockwise). When the set value Vref is greater than
the actual output voltage Vout1 , The LED marked CH1_Work turns from off to
on. This is a critical point. At this time, the actual output voltage
Vout1 of the sensor will be compared with the reference voltage Vref we set.
When the load overcurrent, the actual output voltage exceeds the reference
voltage, the single-chip can detect the overcurrent level signal in time, The
low level will be output on the corresponding I/O port. At this time, the relay
will act once (a tick will be heard), cut the power supply line, and play a
role in timely protection.
u How to set the reference voltage is appropriate:
Here we focus on how to set the reference voltage to compare
with the actual voltage;
There are 2 LED indicators on the board, we briefly describe
the significance of its representation;
(1) CH1_Work LED indicator
u CH1_Work is on when the set reference voltage Vref>
Vout (actual output voltage);
u CH1_Work is off when the set reference voltage Vref
<Vout (actual output voltage);
Through the state of CH1_Work on or off, we can easily judge
the size of the reference voltage at this time, so we can set the reference
voltage we need;
Turn the (+) arrow (clockwise) to turn the adjustable
resistor R17, Vref increases;
Turn the (-) arrow indication (counterclockwise) to turn the
adjustable resistor R17, Vref decreases;
(2) Relay_led indicator
When the solid state relay is turned on, the
Relay_led indicator lights;
When the solid state relay is not conducting,
the Relay_led indicator is off.
(3) What role does the reset button Reset play?
Bounce the button to make it in the UNLOCK state. At this time, the board is in the unlocked state. Then,
if the detected device has an
overcurrent, the relay will be in a repeated switching state (you will hear a
ticking sound continuously).
Press the button to make it in the LOCK state, then if the detected device overcurrent occurs,
the relay will act once (only a ticking sound will be heard) to permanently disconnect the line;
if you
want to unlock the lock state, you need to re-lock Bounce (press Reset), at
this time, switch to UNLOCK state.
(4) No alarm when the tested equipment is working normally,
how to set the "reference voltage" when the alarm exceeds the normal
working current
First of all, after the board is powered on, the power
device of the detected object will start working normally (at the same time,
the key is lifted to make it in the unlocked state). Let us look at the state
of the board CH1_Work at this time;
u If the CH1_Work LED is off at this time, we turn the
adjustable resistor R17 according to the (+) arrow indication (clockwise) until
CH1_Work is on. At this time, we must pay attention to the criticality of
CH1_Work from off to on. The point is that the set reference voltage is close
to the actual output voltage. At this time, the comparator has a pulse signal
output. At this time, because it is in an unlocked state, the relay will switch
repeatedly (you will hear a ticking sound continuously); Set the alarm when the
normal operating current is exceeded. "We must increase the reference
voltage slightly, and turn the adjustable resistor R17 toward the (+) arrow
(clockwise), (the amount of increase needs to be adjusted by the customer
according to the current setting. , In principle, just increase it a little,
don’t over-tighten it. If the reference voltage deviates too far from the
actual output voltage, the comparator has no pulse signal output.) After the
setting is completed, (it must be noted that you must press Red button to make
it in locked state), when the device is abnormal and exceeds the set operating
current, the MCU can detect the overcurrent level signal in time and output a
low level at the corresponding I/O port. At this time, the relay Action once (a
tick will be heard), automatically locked in the protected state, cut the line.
u If the CH1_Work LED is on at this time, we turn the
adjustable resistor R17 toward the (-) arrow indication (counterclockwise)
until the CH1_Work is turned off. At this time, we must pay attention to this.
The critical point is that the set reference voltage is close to the actual
output voltage. At this time, the comparator has a pulse signal output. Because
it is in an unlocked state, the relay will switch repeatedly (you will hear a
ticking sound continuously); we still need to do One thing, turn the adjustable
resistor R17 to the (+) arrow direction (counterclockwise), and turn the
CH1_Work LED to the bright state; in order to set the alarm when the normal
operating current is exceeded, we must increase the reference voltage slightly
, Turn the adjustable resistor R17 toward the (+) arrow (clockwise), (the
amount of increase needs to be adjusted by the customer according to the
current set by him, in principle, increase it a little, don’t over-tighten it.
If The reference voltage deviates too far from the actual output voltage, and
the comparator has no pulse signal output.) After the setting is completed, (it
must be noted that the red button must be pressed at this time to make it in
the locked state). When the working current is fixed, the single-chip can
detect the overcurrent level signal in time, and it will output a low level at
the corresponding I/O port. At this time, the relay will act once (you will
hear a tick), and it will automatically lock in the protection state. Cut the
line.
Sorry! no video to show.
- Shobra Branch : 2
- Heliopolis Branch : 2
- Stock: 4
- Brand: Chinese
- Model: Curr-Limit-Protect-Mod
- Weight: 0.07kg
- SKU: D21-15
- UPC: 2465
- Location: M4-8