Basic Features :

  basic accuracy of the output of up to 0.02% , the output is displayed as 6 -bit

  output function:

DC voltage, DC current, ohms, analog transmitters, thermocouple, RTD, frequency, pulse, switch

  DC current output, can provide 25% and 100% of the manual step, auto step and auto ramp output function

  thermocouple output, can provide high-precision automatic cold junction compensation, ° C or ℉ temperature display

  can be outside with high-precision temperature probe, accuracy: ± 0.2 ° C

  large-screen LCD display multiple data can be displayed simultaneously: DC current and % values, thermocouple, temperature and thermal resistance values ​​corresponding indexing, etc.

  operational performance superior keyboard layout, increase or decrease output setting keys and LCD display set value on the corresponding bit

  using the panel calibration techniques, without opening the chassis can be calibrated

  with white LED backlight, and automatic backlight off and auto power off function, suitable for field use

 

Output of basic technical indicators  [  apply within one year after calibration, 23 ° C ± 5 ° C , 35 ~ 70% RH , accuracy = ± (set value % + range % ) ]

Technology | art | means | Standard |  output function

Function

Range

Output Range

Resolution

Accuracy

PreparationNotes     

DC voltage

DCV

100mV

-10.000 110.000mV

1μV

0.02 + 0.01

Maximum output current 0.5mA

1000mV

-100.00 1100.00mV

10μV

0.02 + 0.01

Maximum output current 2mA

10V

-1.0000 11.0000V

0.1mV

0.02 + 0.01

Maximum output current 5mA

DC Current

DCmA

20mA

0.000 22.000mA

1μA

0.02 + 0.02

At 20 mA , the

Maximum load 1KΩresistance

Analog transmitters, the

External power supply5 ~ 28V

 

Ohm

OHM

400Ω

0.00Ω 400.00Ω

0.01Ω

0.02 + 0.02

Excitation current of± 0.5 ~ 3mA

Excitation current of± 0.1 ~ 0.5mA , add0.1Ω additional error

Accuracy does not contain lead resistance

4KΩ

0.0000 k 4.0000 k

0.1Ω

0.05 + 0.025

Excitation current of± 0.05 ~ 0.3mA

Accuracy does not contain lead resistance

40KΩ

0.000 k 40.000 k

0.1 + 0.1

Excitation current of± 0.01mA

Accuracy does not contain lead resistance

Thermocouple

TC

 

R

° C 1767 ° C

° C

100 ° C :  1.5 ° C

100 1767 ° C : 1.2 ° C

Using ITS-90temperature scale

Accuracy does not contain errors cold junction compensation

S

° C 1767 ° C

100 ° C :  1.5 ° C

100 1767 ° C : 1.2 ° C

K

-200.0 ° C 1372.0° C

0.1 ° C

-200.0 -100.0 ° C:  0.6 ° C

-100.0 400.0 ° C:  0.5 ° C

400.0 1200.0 ° C