Categories

Fluke 1735

Fluke 1735
Product Code: Fluke 1735
Availability: 1
Price: 52,000.00LE
Ex Tax: 52,000.00LE
Qty:     - OR -   Add to Wish List
Add to Compare
Fluke 1735 Three-Phase Power Logger
 
 
Power Quality Recorder, electrical load studies and energy consumption measurement
Fluke 1735 Power Logger is the ideal tool for electricians or technicians engaged in energy studies and basic power quality records. Supplied with the instrument utilizing flexible current probes and color display within a few seconds can be configured to record the vast majority of 1735.1735 power parameters, harmonics and captures voltage events.
 
Application
 
Load studies - verify before adding the load capacity of the new power system
Energy Assessment - Before installing energy-saving equipment, power consumption values ​​after
Harmonic measurement - find harmonic problems caused equipment damage or malfunction
Captures voltage events - Monitoring will cause a reset switch or circuit breaker operation erroneous dips and swells event
 
 
Fluke 1735 Three-Phase Power Logger
 
 
 
Record length to 45 days of power and associated parameters
Monitor maximum power demand interval based on the average time a user-defined
Energy consumption tests to prove the effect of energy saving
Measurement of harmonic distortion caused by electronic loads
Load switching by capturing voltage dips and swells due to increase reliability
Instrument settings can be easily confirmed by the color of waveforms and trends
Use four flexible current probe to measure all three phases and neutral
Use with the instrument supplied Power Log software to observe and generate graphical reports
Compact, rugged design, IP65 grade enclosure, 600 V CAT III protection level, 2-year warranty
 

 

Technical Specifications
General
Show ¼ VGA graphics, color display (320 x 240 pixels), text, graphics, adjustable contrast
Quality According to DIN ISO 9002 development, design, manufacture
Storage 4 MB Flash memory, 3.5 MB available for storing measurement data
Interface RS-232 SUB-D socket; 115.2 k baud, 8 stop bit, no parity, 1 stop bit, through the RS- 232 interface hardware upgrades (10-pin cable)
Sampling rate 10.25 kHz
Frequency 50 Hz or 60 Hz, user-selectable, automatic synchronization
Power supply NiMH battery pack, AC adapter (15 V ~ 20 V / 0.9 A)
Battery Typical> 12 h, with no backlighting,> 7 h with backlight
Size 240 mm x 180 mm x 110 mm
Weight 1.7 kg, including batteries
Environment
Operating Temperature Range -10 ° C to +51 ° C
Storage temperature range -20 ° C to +60 ° C
Operating Temperature Range 0 ° C to +40 ° C
Reference temperature range 23 ° C ± 2 ° C
Watch out Based on the above conditions the European standard. At any point in the operating temperature is calculated using the temperature coefficient specifications
Temperature Coefficient Measured value ± 0.1% per ° C reference value
Inherent error Under reference conditions, the maximum error, guarantee period of 2 years
Operating error Reference operating temperature range, the maximum error, the shelf life of 2 years
Climate rating C1 (IEC 654-1) -5 ° C ~ +45 ° C, 5% ~ 96% RH, non-condensing
Chassis After the earthquake, the thermoplastic scratch test, V1-type (non-flammable) with rubber protective shell
EMC
Radiation  
Interference  
Security
Security IEC 61010-1 600 V CAT III, reinforced double insulation, protection level 3
Protection IP65; EN60529 (refers only without battery power rack)
  RMS values ​​are measured with a resolution of 20 ms to RMS measurement
V-rms wye measurement
Measurement Range  
Inherent error ± (0.2% measured value + 5 words)
Operating error ± (0.5% of mv + 10 words)
Resolution  
V-rms delta measurement
Measurement Range  
Inherent error  
Operating error  
Resolution  
A-rms measurement
Flexible current probes Range:  
Current Clamp Range:  
Resolution  
   
Inherent error  
Operating error  
   
Inherent error  
Operating error  
  Error current probe is not included
Use a flexible probe kit
Flexible probe measurement error  
Position on  
CF (typical):  
Watch out When using a flexible probe sure the wire lock position to influence the flexible probe
Power measurements (P - Active, S - apparent, Q- reactive, D - distortion)
Measurement Range See V rms and A rms measurement
  Calculated based on the voltage and current error
  The additional error caused by the power factor PF
  Error x (1- [PF])
  When the maximum voltage range is 830 V (delta- connection), the current range is 3000 A is 2.491 MW, the maximum display value may be displayed when PTs and CTs use with variable ratio
Inherent error  
Resolution  
Operating error  
  Typical voltage connection (230 V wye), current 150 A is 34.51 KW.
Inherent error  
Resolution  
Operating error  
  The error of the current sensor is not considered
Energy measurement (kWh, KVAh, kVARh)
Inherent error  
Resolution  
Operating error  
  Frequency error
PF Power Factor
Range  
Resolution  
Accuracy ± 1% of full scale
Frequency Measurement
Measurement Range  
Inherent error  
Operating error  
Resolution  
Harmonics
Measurement Range To the 50th harmonic (<51% of nominal value)
Accuracy
   
Vm ≥ 3% Vn: ± 5% Vm
Vm <3% Vnom: ± 0.15% Vnom
Im ≥ 10% Inom: ± 5% Im
Im <10% Inom: ± 0 5% Inom
THDV: For THD <3% ± 0.15%, Vnom 
for THD ≥ 3% ± 5%, Vnom
THDI: For THD <10% ± 0.5%, Inom 
for THD ≥ 10% ± 5%, Inom
  Nominal voltage range
  Nominal current range
  Vm and Im m times harmonic measurements
Event
   
Inherent error  
Operating error  
Resolution 0.1 V
 

Write a review

Your Name:


Your Review: Note: HTML is not translated!

Rating: Bad           Good

Enter the code in the box below:



Powered By OpenCart
UGE Electronics Co. Egypt ( Arduino Egypt Solar PV Cell 3D printer CNC , Low Price) © 2017