This Model Is Discontinued and replaced with AT8611 DC Electronic Load for AT8511 DC Electronic Load Click Here
AT8511 DC Electronic Load
|
| |
| AT8511 DC electronic load using multiple processors to work together, have excellent speed and performance. Provides four load operating mode (CC, CV, CP, CR), and can edit the file comprehensive tests. AT8511 powerful processor system, regardless of multi-mode multi-file processing, or cope with the PC communications are more than enough. Dynamic test function, a list of test functions and integrated test functions , so 8511 has a wide test applications. Inside the instrument file with the editor or using the computer operating software, document preparation and more easy to use. Support for the latest USB interface and traditional RS232C interface, and can achieve multi-machine communication. Compatible with standard SCPI protocol to make computer programming more convenient. In addition to the normal linear power supply and switching power supply for testing outside, AT8511 also better for the battery charger, battery testing, power supply manufacturers to meet the diversified demands.
|
![]() |
|
| Promotion |
| Technical Specifications |
| ● |
Rated input: 150W, 120V, 30A |
| ● |
Constant current (CC): |
| ● |
0 ~ 3A, Accuracy: 0.05%, the minimum resolution: 0.0001A |
| ● |
0 ~ 30A, Accuracy: 0.1%, the minimum resolution: 0.001A |
| ● |
Constant voltage (CV): |
| ● |
0 ~ 120V, Accuracy: 0.05%, the minimum resolution of 0.001V |
| ● |
0 ~ 120V, Accuracy: 0.05%, the minimum resolution 0.01V |
| ● |
Constant power (CP): |
| ● |
0 ~ 100W, accuracy: 1%, minimum resolution: 0.001W |
| ● |
100 ~ 150W, accuracy: 1%, minimum resolution: 0.01W |
| ● |
Constant Resistance (CR): |
| ● |
0.1 ~ 99Ω, accuracy: 1%, minimum resolution: 0.01Ω |
| ● |
100 ~ 4kΩ, accuracy: 1%, minimum resolution: 0.1Ω |
| ● |
Voltmeter accuracy: 0.02% |
| ● |
Ammeter Accuracy: 0.1% |
| ● |
Test speed: 3 times / sec, 10 times / sec |
|
| Performance characteristics |
| ● |
Short-circuit test: current is about 30A, the internal resistance of approximately 40mΩ |
| ● |
Dynamic test: 10 files, 0.1Hz ~ 1kHz |
| ● |
Dynamic list of tests: 10 files, 100 steps / file |
| ● |
A comprehensive list of tests: 10 files, 20 steps / file |
| ● |
Battery Test: 999.99AH |
| ● |
Global Settings File: 20 groups |
| ● |
Triggers: internal trigger, bus trigger and external trigger |
| ● |
Interface: USB interface and standard RS232C and Handler Interface |
| ● |
Programming Language: SCPI and simple communication protocol |
| ● |
Display: VFD display |
| ● |
Support 4W remote measurement function |
|
| Application |
| ● |
Aging test switching power supplies and linear power supplies |
| ● |
Chargers Comprehensive Test |
| ● |
Battery capacity test |
|
Reviews