HIOKI BT3554-50-Portable Battery Tester

SKU: TAR-ST-BT3554-51
In Stock
EGP 225,378.000
In Stock
Brand:hioki

HIOKI BT3554-51-Portable Battery Tester

  • Portable battery tester for field and industrial use
  • Measures internal resistance (AC‑IR at 1 kHz) and DC voltage
  • Rapid measurement: results in under 2 seconds
  • No battery disconnection needed during testing
  • PASS / WARNING / FAIL comparator for quick diagnostics
  • Internal memory for storing thousands of readings
  • USB / Bluetooth connectivity for easy data transfer
  • Rugged, compact design with ergonomic handling
  • Ideal for UPS, lead-acid, VRLA, and backup power batteries

Description

HIOKI BT3554-50-Portable Battery Tester

The new Battery Tester BT3554-50 sets a new standard for UPS and lead-acid battery diagnostics. Since the battery’s internal resistance and voltage are measured using the impedance method, diagnostics can be performed while the battery is connected to its host device, without taking it offline. Proprietary noise reduction technology allows more accurate measurement, even in noisy environments.

HIOKI BT3554-50-Portable Battery Tester-1

HIOKI BT3554-50-Portable Battery Tester-1

Basic specifications

Accuracy guaranteed: 1 year
BT3554-50 BT3554-51 BT3554-52
Resistance measurement range 3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges
Accuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt)
Testing source frequency: 1 kHz ±30 Hz
With function for avoiding noise frequency enabled: 1 kHz ±80 Hz
Testing current: 160 mA (3m/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range)
Open terminal Voltage: 5 V peak
Voltage measurement range ± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08 % rdg ±6 dgt
Temperature measurement accuracy Measurement range: -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F), Measurement accuracy*: ±1.0°C (±1.8°F)
* When using the Clip Type Lead with Temperature Sensor 9460.
* When using the Temperature Probe 9451, add ±0.5°C (±0.9°F) (cable length: 1.5 m [59.1″]).
* When using the Temperature Probe 9451S, add ±0.5°C (±0.9°F) (cable length: 0.1 m [3.94″]).
BT3554-50 standalone accuracy with simulated input: ±0.5°C (±0.9°F)
Absolute max. input voltage 60 V DC max. (No AC input)
Measurement time 100 ms
Response time Approx. 1.6 sec.
Comparator Compares measured values with set threshold values to make judgments and reports them to the user.
Judgment notification method: Results are displayed as shown below (segment) and beeping tones sound
When the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL
When the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL
If the judgment result is WARNING or FAIL, the audio tone is accompanied by a red backlight.
User-selectable voltage judgment method: ABS (absolute value judgment), POL (polarity judgment )
Savable settings: 200 tables
Memory functionality Operation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units)
Saved data: Saved measurement data is linked to profile information.1. Measurement data: Data can be saved, loaded, and deleted by operating the instrument.
-1. Date and time
-2. Resistance value, voltage value, and temperature
-3. Comparator threshold value and judgment result2. Profile information: Profile information can be saved, loaded, and deleted using a supported application (GENNECT Cross or GENNECT One).
-1. Profile numbers: 1 to 100 (Data (2), (3), and (4) below are saved for each profile number)
-2. Location: User-defined comment such as location of UPS
-3. Device information: User-defined comment such as UPS management number
-4. Battery number: 1 to 500 (start number, end number)
Measurement Navigator Operation: Announces the next battery number to be measured via a screen display and audio guidance.
Audio output is generated by a connected mobile device when using the Z3210 and a supported application (GENNECT Cross).
Preparations: Profile information that’s been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument.
Communication interface USB
Bluetooth® wireless communications (when Z3210 installed)
Other functions Temperature measurement (-10.0 to 60.0 °C), Zero-adjustment, Hold, Auto-hold, Auto-memory, Auto-power-save, Clock
Power supply LR6 (size AA) alkaline battery ×8
Rated supply voltage: 1.5 V DC × 8
(Nickel metal hydride batteries may be used. However, the battery life display is not supported in this configuration.)
Continuous operating time: Approx. 8.3 hr. (without Z3210 installed), Approx. 8.2 hr. (with Z3210 installed and wireless communications active)
Dimensions and mass 199 mm (7.83 in.)W × 132 mm (5.20 in.)H × 60.6 mm (2.39 in.)D (with protector), 960 g (33.9 oz.) (including batteries and protector)
Included accessories Carrying Case C1014 ×1, Protector Z5041 ×1, Fuse Set Z5050 ×1, 0 Adj Board ×1, Neck strap Z5043×1, USB cable L1003 ×1, AA alkaline battery (LR6) ×8, User Manual ×1