Fluke 1507 Insulation Resistance Tester

SKU: Fluke 1507
In Stock
EGP 66,000.000 exc. vat
In Stock

Brand:Fluke

Description

Fluke 1507 Insulation Resistance Tester

AC/DC Voltage Measurement
AccuracyRange600.0 V
Resolution0.1 V
50 Hz to 400 Hz ± (% of Rdg + Digits)±(2% + 3)
Input impedance3 MΩ (nominal), < 100 pF
Common mode rejection ratio (1 kΩ unbalanced):> 60 dB at DC, 50 or 60 Hz
Overload protection600 V rms or DC
Earth Bond Resistance Measurement
Range/Resolution20.00 Ω0.01 Ω
200.0 Ω0.1 Ω
2000 Ω1.0 Ω
20.00 kΩ0.01 kΩ
Accuracy±(1.5% + 3)
Overload protection2 V rms or DC
Open circuit test voltage> 4.0 V, < 8 V
Short circuit current> 200.0 mA
Insulation Specifications
Measurement range0.01 MΩ to 10 GΩ
Test voltage50 V, 100 V, 250 V, 500 V, 1000 V
Test voltage accuracy+ 20%, – 0%
Short circuit current1 mA nominal
Auto dischargeDischarge time < 0.5 second for C = 1 µF or less
Live circuit indicatorInhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive loadOperable with up to 1 µF load
Measure accuracy50 V±(3% + 5)
100 V±(3% + 5)
250 V±(1.5% + 5)
500 V±(1.5% + 5)
1000 V±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ
General Specifications
Maximum voltage applied to any terminal:600 V AC rms or DC
Storage temperature-40°C to 60°C (-40°F to 140°F)
Operating temperature-20°C to 55°C (-4°F to 131°F)
Temperature coefficient0.05 x (specified accuracy) per °C for temperatures < 18°C or > 28°C (< 64°F or > 82°F)
Relative humidity
0% to 95% @ 10°C to 30°C (50°F to 86°F)
0% to 75% @ 30°C to 40°C (86°F to 104°F)
0% to 40% @ 40°C to 55°C (104°F to 131°F)
VibrationRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Shock1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)
Electromagnetic compatibilityIn an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)
SafetyComplies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
CertificationsCSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
BatteriesFour AA batteries (NEDA 15A or IEC LR6)
Battery lifeInsulation test use:Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements:Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L)5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight550 g (1.2 lb)
IP ratingIP40
AltitudeOperating2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage)12,000 m
Over-range capability110% of range
Included accessoriesTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe

Additional information

Weight1.65 kg

Brand

Fluke

Fluke
Fluke

Reviews

There are no reviews yet.

Be the first to review “Fluke 1507 Insulation Resistance Tester”

Refund Policy for UGE Electronics “Https://uge-one.com “

 

1. Returns and Refunds

Thank you for shopping at UGE Electronics “Https://uge-one.com “. If you are not entirely satisfied with your purchase, we’re here to help.

 

2. Eligibility for Refund

To be eligible for a refund, please make sure that:

– The item was purchased in the last 14 days.

– The item is in the original packaging.

– The item isn’t used or damaged.

 

3. How to Initiate a Refund

To initiate a refund, please contact our customer support at [[email protected]] or [01066552125]. Provide your order number and details about the product you would like to return.

 

4. Refund Processing Time

Once we receive your item, we will inspect it and notify you that we have received your returned item. We will immediately notify you on the status of your refund after inspecting the item.

If your return is approved, we will initiate a refund to your credit card (or original method of payment). You will receive the credit within a certain amount of days, depending on your card issuer’s policies.

 

5. Shipping Costs

Shipping costs are non-refundable. If you receive a refund, the cost of return shipping will be deducted from your refund.

 

6. Exchanges

If you wish to exchange an item, please contact our customer support. You will be responsible for the return shipping costs, and we will cover the shipping costs of the replacement item.

 

7. Damaged or Defective Items

If you received a damaged or defective product, please contact us immediately for assistance. We will work with you to resolve the issue promptly.

 

8. Contact Information

If you have any questions about our Refund Policy, please contact us at [[email protected]].

 

Important Note: This Return & Refund Policy is applied only for Orders invoiced VIA UGE Electronics, and regarding any Orders has been invoiced VIA any Other Vendor you can check the Return & Refund Policy of this Vendor VIA the Vendor Stroe Page, and it’s not our responsibility for any issue between you and the Vendor.

Product Enquiry

Please Login to make enquiry about this product
Fluke 1507 Insulation Resistance Tester
Fluke 1507 Insulation Resistance Tester EGP 66,000.000 exc. vat
In Stock