Fluke 1550C 5 kV Digital Insulation Tester

SKU: TAR-ST-FLUKE1550C
In Stock
EGP 192,000.000
In Stock
Brand:Fluke

Fluke 1550C  5 kV Digital Insulation Tester

    • Performs insulation resistance testing up to 5 kV

    • Measures resistance up to 1 TΩ

    • Ideal for testing motors, generators, switchgear, and high-voltage cables

    • Features large digital/analog LCD display

    • Stores up to 99 test results for easy recall

    • Includes DAR and PI automatic calculations

    • Guard terminal reduces surface leakage errors

    • Safety rated CAT III 1000 V / CAT IV 600 V

    • Provides live-circuit warning up to 600 V for user safety

    • Long-lasting battery supports over 750 tests per charge

    • Includes timed tests up to 99 minutes

Description

Fluke 1550C 5 kV Digital Insulation Tester

The Fluke 1550C insulation resistance tester offers digital insulation testing up to 5 kV, making them ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables.

Fluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class and CAT IV 600 V safety rating. With measurement storage and PC interface, the 1550C is the perfect tool for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.

Fluke 1550C 5 kV Digital Insulation Tester

  • Features include:

    • Test voltages to up 5 kV and save time by trending on the spot only with Fluke Connect™
    • CAT III 1000 V, CAT IV 600 V safety rating
    • Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
    • Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
    • Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
    • Long battery life gives the user over 750 tests between charges
    • Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
    • Guard system eliminates the effect of surface leakage current on high-resistance measurements
    • Large digital/analog LCD for easy viewing
    • Capacitance and leakage current measurement
    • Ramp function for breakdown testing
    • Resistance measurements up to 2 TΩ
    • Timer settings up to 99 minutes for timed tests

     

  • Electrical Specifications
    The tester’s accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ± .25% per °C, except on the 20% bands add ± 1% per °C.
    Insulation Resistance Measurement
    Test voltage (DC)
    250 V Range < 250 kΩ,
    250 kΩ to 5 GΩ
    5 GΩ to 50 GΩ
    > 50 GΩ
    Accuracy (± reading) Unspecified
    5%
    20%
    Unspecified
    500 V Range < 500 kΩ
    500 kΩ to 10 GΩ
    10 GΩ to 100 GΩ
    > 100 GΩ
    Accuracy (± reading) Unspecified
    5%
    20%
    Unspecified
    1000 V Range < 1 MΩ
    1 MΩ to 20 GΩ
    20 GΩ to 200 GΩ
    > 200 GΩ
    Accuracy (± reading) Unspecified
    5%
    20%
    Unspecified
    2500 V Range < 2.5 MΩ
    2.5 MΩ to 50 GΩ
    50 GΩ to 500 GΩ
    > 500 GΩ
    Accuracy (± reading) Unspecified
    5%
    20%
    Unspecified
    5000 V Range < 5 MΩ
    5 MΩ to 100 GΩ
    100 GΩ to 1 TΩ
    > 1 TΩ
    Accuracy (± reading) Unspecified
    5%
    20%
    Unspecified
    Bar graph range 0 to 1 TΩ (1550C) – 0 to 2 TΩ (1555)
    Insulation test voltage accuracy -0%, +10% at 1 mA load current
    Induced AC mains current rejection 2 mA maximum
    Charging rate for capacitive load 5 seconds per μF
    Discharge rate for capacitive load 1.5 s/μF
    Leakage current measurement Range 1 nA to 2 mA
    Accuracy ± (5% + 2 nA)
    Capacitance measurement Range 0.01 μF to 15.00 μF
    Accuracy ± (15% rdg + 0.03 μF)
    Timer Range 0 to 99 minutes
    Resolution setting 1 minute
    Resolution indication 1 second
    Live circuit warning Warning range 30 V to 660 V AC/DC, 50/60 Hz
    Voltage accuracy ± (15% + 2 V)
    Software specifications FlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.
    General Specifications
    Display 75 x 105 mm
    Power 12 V lead-acid rechargeable battery, Yuasa NP2.8-12
    Charger Input (AC) 85 V to 250 V AC 50/60 Hz 20 VA
    This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.
    Dimensions 269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)
    Weight 3.7 kg (8.2 lb)
    Temperature (operating) -20°C to 50°C (-4°F to 122°F)
    Temperature (storage) -20°C to 65°C (-4°F to 149°F)
    Humidity 80% to 31°C decreasing linearly to 50% at 50°C
    Altitude 2000 m
    Enclosure sealing IP40
    Input overload protection 1000 V AC
    Electromagnetic compatibility EN 61326
    Safety compliance IEC 61010-1: Overvoltage category II, Pollution Degree 2.
    IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III
    IEC 61557-1, IEC 61557-2

Brand

Fluke

Fluke
Fluke

Reviews

There are no reviews yet.

Be the first to review “Fluke 1550C 5 kV Digital Insulation Tester”
Fluke 1550C 5 kV Digital Insulation Tester
Fluke 1550C 5 kV Digital Insulation Tester EGP 192,000.000
In Stock