Item(s) left: -1
12 kinds of electrical testing power management and applications, including harmonic analysis can be carried out, including power quality management. A key operation is very simple, you can use the included set / analysis software to easily handle complex and large data set. External signal input / output functions can send a signal to the alarm. Using the memory backup function, even in the record, the CF card can still insert / pull (1GB). True RMS display. Two kinds of power supply: AC power and battery power (can use rechargeable batteries). Use leakage current sensor (optional) can be insulated to monitor current. Recording function selectable from 1 second to 1 hour recording interval: 1/2/5/10/15/30 seconds, 1/2/5/10/15/30 minutes, one hour of data can be stored on the 1GB memory card the. (Via USB (software) to download data to a PC).
![]()
![]()
![]()
![]()
![]()
![]()

Record display screen capture functionality (using the CF card can record 512 screens: a screen 40KB)
Waveform and vector displays can also confirm wiring.
Designed to meet international safety standards IEC61010-1 CAT.III 600V
|
Wiring
|
Single-phase 2-wire (4 loops) / single-phase three-wire / three-phase three-wire (two loops)
three-phase four-wire / single-phase three-wire and three-phase three-wire (Scott wiring) |
|
Test function
|
Voltage, current, frequency, active power, reactive power, apparent power,
active power, reactive power, apparent power, power factor, power quality (harmonics / unbalance / transient / voltage drop / voltage rise / interrupt ) Phase proceeds capacitors, IEC flicker (Pst (1 minute *), Pst, Pit)
* Pst be displayed every 1 minute detail
|
|
Voltage Range
|
150/300/600 / 1000V
|
|
Current Range
|
8128 (50A): 1/5/10/20 / 50A
8127 (100A): 10/20/50 / 100A
8126 (200A): 20/50/100 / 200A
8125 (500A): 50/100/200/500 / 1000A
8124 (1000A): 100/200/500 / 1000A
8129 (3000A): 300/1000 / 3000A
|
|
Accuracy
|
Voltage: ± 0.2% rdg ± 0.1% fs,
Current: ± 0.2% rdg ± 0.1% fs + Clamp Sensor Accuracy
Active: ± 0.5% rdg ± 0.1% fs + Clamp Sensor Accuracy
|
|
Power factor affecting
|
± 1.0% rdg cosθ = ± 0.5 (PF = 1)
|
|
Frequency Range
|
40 ~ 70Hz
|
|
Time recording interval
|
1/2/5/10/15/30 sec 1/2/5/10/15/30 minutes, 1 hour
|
|
Memory Capacity
|
1.8MB (test file: CSVx6 picture file: BMPx7 setup file: KASx20)
|
|
Show
|
3.5-inch color STN display LCD (320 x 240)
|
|
Language
|
Chinese / Japanese / English
|
|
Storage temperature and humidity range
|
-20 ~ 60 ℃, less than 85% RH (non-condensing)
|
|
Operating temperature and humidity range
|
0 ~ 50 ℃, less than 85% RH (non-condensing)
|
|
Other
|
DC input port (50mV / 500mV / 5V)
|
|
PC Card
|
Micro Memory Card (CF card): 32MB / 64MB / 128MB / 256MB / 1GB
|
|
Safety Specifications
|
IEC61010-1: 2001 CAT.Ⅲ 600V Pollution degree 2
IEC61010-031 IEC61326 |
|
Power supply
|
AC100V ~ 240V ± 10% (45 ~ 65Hz), alkaline batteries AA LR6 (9V 1.5V x 6) or Ni-MH (HR15-51)
|
|
Dimensions
|
175 (L) x 120 (W) x 68 (D) mm
|
|
Accessories
|
7141B (voltage test line) 7170 (power line) 8319 (reader) 7148 (USB connection)
9125 (carrying case) leads stickers × 32 830 (CF card MB) input port Sticker single three batteries × 6 × 6
PQA MASTER (PC software) Operating Instructions
|
|
Optional
|
8306 (CF card 64MB) 8322 (CF card 256MB) 8323 (CF card 1GB) 8124/8215/8126/8127/8128 (load current sensor) 8129 (load current flexible sensor) 8146/8147/8148 (leakage current & load current sensor) 8141/8142/8143 (leakage current sensor) 8312 (power adapter) 9132 (magnet carrying case) 8325F (Flicker sensor) |
| Weight | 0.196 kg |
|---|
You must be logged in to post a review.
Reviews
There are no reviews yet.