Using the Instek GPT 9601 AC 100VA AC Withstanding Voltage Tester The suppression of temperature rise during heavy-duty operation of the tester significantly increases tester’s reliability and service lifetime. The 240 x 48 display clearly shows the applied voltage, test parameters, test conditions, measurement value and result on the screen at the same time.
GW Instek launches new economical safety testers, the GPT-9600 Series, which offers an affordable solution for supporting routine tests of major items of the safety standards such as IEC, EN, UL, CSA, GB, JIS and other safety regulations.
The GPT-9600 Series is built upon a platform of 100VA AC maximum power output. The GPT-9602 is capable of performing AC and DC withstanding test. The GPT-9600 Series is equipped with the high-efficiency PWM amplifier, which is the core of the platform design to impede the influence from the input AC voltage fluctuation and ensure a stable voltage output.
Following a tidy and easy-to-use design concept, the GPT-9600 Series renders users an intuitive operation environment by a simple and clear panel layout, a large LCD display and color LED indicators. The switching power supply, used as a universal input source, accommodates the power systems in most countries in the world. Unlike other members of GW Instek Safety Testers, the GPT-9600 Series uses a preset output voltage bar to indicate the expected output voltage for withstanding voltage tests instead of the traditional AC slide operation and indication. Furthermore, an AUTO mode, including test sequence selections of withstanding-then-insulation or insulation-then-withstanding, is designed for models carrying insulation Resistance test function to reduce the testing time of dual test items.
Other functions and features of GPT-9600 include: the zero crossing turn-on operation protects DUT from the impact of surge voltage output, the interlock function safeguards users from the hazardous shock of unintentional touch of the voltage output, a remote output on-off terminal in the front panel and a signal I/O port in the rear panel are provided as the means for remote start/stop control of the safety tester.
GPT-9600 Series Features
High Efficiency and High Stability Output
The GPT-9600 Series, carrying a high-efficiency PWM amplifier design, generates output source up to 98% efficiency. This greatly reduces the energy loss from heat dissipation and therefore lowers the temperature within the cabinet. The suppression of temperature rise during heavy-duty operation of the tester significantly increases tester’s reliability and service lifetime.
PWM Amplifier Efficiency
Friendly User Interface
The 240 x 48 display clearly shows the applied voltage, test parameters, test conditions, measurement value and result on the screen at the same time. The real-time status update on the LCD display accompanied by the multi-colored LED status indicators on the front panel allow operators to have a full control of the test process to perform precession test and avoid unnecessary operation risks at the same time. The status indicator above the high voltage output terminal will automatically flash when an output is in place. In addition, the function keys arranged below the LCD display provide convenient operation that test functions can be easily changed by a single pressing.
Large LCD, High Intensity Indicators and Function Keys
Simply AUTO Mode
For models that include the Insulation Resistance test function; there is a simple AUTO mode (W-I or I-W) which allows the operator to run two test functions in sequence. The first test function can either be a withstanding voltage test followed by an insulation resistance test or vice versa, – thus eliminating the need to push the START button twice to run two separate tests.
Simply AUTO Mode
Support the Universal Input Voltage
Additionally, the GPT-9600 series provide Additionally, the GPT-9600 series provides the universal input voltage range for operating equipment in countries with different electrical power standards. With the GPT-9600 series, the hustle of switching or selecting input voltage range can be left behind. Furthermore, 50Hz or 60Hz can be selected to provide a stable and appropriate test voltage without relying on the electrical environment conditions of input power so as to meet the test requirements.
Manufacturer Specs
| Selection Guide of the GPT-9600 Series | ||||
| Model | GPT-9601 | GPT-9602 | GPT-9612 | GPT-9603 |
| Output Capacity | 100VA | |||
| AC Withstanding (ACW) | 5kVac 20mA |
5kVac 20mA |
5kVac 20mA |
5kVac 20mA |
| DC Withstanding (DCW) | —— | 6kVdc 6mA |
—— | 6kVdc 6mA |
| Insulation Resistance (IR) | —— | —— | 50 /100/250/ 500/1000Vdc 2000MΩ |
50/100/250/ 500/1000Vdc 2000MΩ |
| Ground Bond (GB) | —— | —— | —— | —— |
| ARC Detection | YES | YES | YES | YES |
| Ramp-Up Function | 0.1s Fixed | 0.1s Fixed | 0.1s Fixed | 0.1s Fixed |
| Memory Storage for Setting | 1 | 2 | 2 | 3 |
| AUTO Mode | —— | —— | AC-IR or IR-AC | AC-IR or IR-AC DC-IR or IR-DC |
| Safety Interlock | YES | YES | YES | YES |
| Remote Terminal | YES | YES | YES | YES |
| Signal I/O | YES | YES | YES | YES |
| USB/RS232C Interface | —— | —— | —— | —— |
| GPIB Interface | —— | —— | —— | —— |
| Display, LCD | 240 x 48 | 240 x 48 | 240 x 48 | 240 x 48 |
| CE Compliance | YES | YES | YES | YES |
| AC Withstanding Voltage [for all models] | |||
| Output-Voltage Range | 0.10kV~ 5.00kV | ||
| Output-Voltage Resolution | 10V | ||
| Maximum Rated Load | 100 VA (5kV/20mA) | ||
| Maximum Rated Current | 20mA (0.5kV | ||
| Output-Voltage Waveform | Sine wave | ||
| Output-Voltage Frequency | 50 Hz / 60 Hz selectable | ||
| Voltage Regulation | ± (1.5% + 2 counts) [full load ->no load] | ||
| Voltmeter Accuracy | ± (1.5% of reading + 2 counts) | ||
| Current Measurement Range [1] | 0.01mA~20.0mA | ||
| Current Best Resolution | 0.01mA(0.01mA~9.99mA) 0.1mA(10.0mA~20.0mA) |
||
| Current Measurement Accuracy | ± (2.0% of rdg + 5 counts) when HI SET<1.00mA ± (2.0% of rdg + 3 counts) when HI SET=1.00mA |
||
| Window Comparator Method | Yes | ||
| ARC Detect | Yes | ||
| RAMP (Ramp-Up Time) | 0.1s Fixed | ||
| TIMER (Test Time) | OFF, 1s~180s | ||
| GND | ON | ||
| [ 1 ] Output Limitation in AC Withstanding Voltage Testing as below. | |||
| Upper Current | Pause | Output Time | |
| AC | 15mA≦I≦20mA | At least as long as the output time | Approx. 180 seconds |
| 0.01mA≦I<15mA | Not necessary | Continuous output possible | |
| DC Withstanding Voltage [for GPT-9602/9603] | |||
| Output-Voltage Range | 0.10kV~ 6.00kV | ||
| Output-Voltage Resolution | 10V | ||
| Maximum Rated Load | 25W (5kV/5mA) | ||
| Maximum Rated Current | 6mA (0.5kV | ||
| Voltage Regulation | ± (1.5% + 2 counts) [full load ->no load] | ||
| Voltmeter Accuracy | ± (1.5% of reading + 2 counts) | ||
| Current Measurement Range [1] | 0.01mA~6.00mA | ||
| Current Best Resolution | 0.01mA(0.01mA~6.00mA) | ||
| Current Measurement Accuracy | ± (2.0% of rdg + 5 counts) when HI SET<1.00mA ± (2.0% of rdg + 3 counts) when HI SET=1.00mA |
||
| Window Comparator Method | Yes | ||
| ARC Detect | Yes | ||
| RAMP (Ramp-Up Time) | 0.1s Fixed | ||
| TIMER (Test Time) | OFF, 1s~180s | ||
| GND | ON | ||
| [ 1 ] Output Limitation in DC Withstanding Voltage Testing as below. | |||
| Upper Current | Pause | Output Time | |
| DC | 0.01mA≦I≦6.00mA | Not necessary | Continuous output possible |
| Insulation Resistance | [for GPT-9612/9603] | |
| Output Voltage | 50V/100V/250V/500V/1000V | |
| Output-Voltage Accuracy | ± (3.0% of setting + 1 count) with no load | |
| Voltage Regulation | ± (1.5% + 2 counts) [full load ->no load] | |
| Voltmeter Accuracy | ± (1.5% of reading + 2 counts) | |
| Resistance Measurement Range | 1MO~ 2000MO | |
| Test Voltage | Measure Range | Accuracy |
| 50V / 100V / 250V | 1~50MΩ 51~2000MΩ |
± (5% of reading + 2MΩ) ± (10% of reading + 2MΩ) |
| 500V / 1000V | 1~500MΩ 501~2000MΩ ± (5% of reading + 2MΩ) |
± (10% of reading + 2MΩ) |
| Output Impedance | 600kΩ | |
| Window Comparator Method | Yes | |
| RAMP (Ramp-Up Time) | 0.1s Fixed | |
| TIMER (Test Time) | 1s~180s | |
| GND | OFF | |
| General | ||
| Note | The specifications apply when the GPT-9600 series are powered on for at least 30 minutes at 15°C~35°C. | |
| Display | 240 x 48 Ice Blue dot matrix LCD | |
| AUTO Mode* | AC-IR / IR-AC / DC-IR / IR-DC | |
| Interface | Remote, Signal I/O | |
| Power Source | AC 100-120 V / 220-240 V ±10% | |
| Power Line Frequency | 50/60Hz | |
| Power Consumption | Max 400VA | |
| Dimensions | 322(W) x 148(H) x 385(D) mm | |
| Weight | Approx. 9kg max. | |
| * The available Auto mode depends on the selected model | ||
| Environment | ||
| Note | To operate over the specific temperature range may cause damage to the circuit. And, do not use in a place where strong magnetic or electric field exists. | |
| Warranty Environment | 15°C to 35°C, Humidity 70% (no condensation) | |
| Operation Environment | 0°C to 40°C, Humidity 70% (no condensation) | |
| Storage Environment | -10°C to 70°C, Humidity 85% (no condensation) | |
| Installation Location | Indoors at an amplitude of up to 2000m | |
Tech Specs
| Safety Testing / Surge Testing/Hipot Tester Template | |
| Test Type Hipot | AC |
| Max AC Test Voltage | 5 kV |
| Max Trip Current AC Test | 20 mA |
| Programmable (hipot) | No |
| Insulation Resistance Test | No |
| Connection Type | Probe |
| Arc Detection | Yes |
| Scanning control capable for Multipoint Testing | No |
| Test Equipment General Attributes | |
| Unique Features | AC 100VA AC Withstanding Voltage Tester |
| Warranty | 1 YEARS |
| Interfaces I/O | Remote Sense |
| Product Weight | 20 LBS |
| Product Height | 148 MM (5.83 IN) |
| Product Length | 385 MM (15.16 IN) |
| Product Width | 322 MM (12.68 IN) |
| Data Logging | No |
| HTS/Schedule B Number | 9030.33.3400 |
| ECCN Number | 3A992 |
| Calibration Included | Factory Calibration |
| Power Supply Voltage | 120V/220V Universal |