Fluke 1736 Three-Phase Power Logger with Fluke Connect

Model: Fluke 1736
SKU: INK-Fluke-1736
In Stock
EGP 521,000.000
In Stock
SKU: INK-Fluke-1736 Category:

Description

The Fluke 1736 Three-Phase Power Logger is a professional power and energy logging instrument designed for conducting energy studies, load studies, and basic power quality analysis. It automatically captures and logs voltage, current, power, energy, power factor, harmonics, THD, and other important electrical parameters.

Key Features:

– Three-phase power and energy logging
– Automatically captures and logs over 500 power quality parameters
– Measures Voltage, Current, Power, Energy, Power Factor and Frequency
– Voltage Range: up to 1000 V
– Voltage Resolution: 0.1 V
– Voltage Accuracy: ±(0.2% + 0.01% of full scale)
– Frequency Range: 42.5 Hz to 69 Hz
– Frequency Resolution: 0.01 Hz
– Current Measurement: up to 6000 A depending on connected current probe
– 4 Voltage Inputs: 3 phases + neutral
– 4 Current Inputs
– 2 Auxiliary Inputs: 0 to ±10 V DC
– Measures Active Power (W)
– Measures Reactive Power (var)
– Measures Apparent Power (VA)
– Measures Active, Reactive and Apparent Energy
– Power Factor (PF) and Displacement Power Factor (DPF)
– Voltage and Current THD measurement
– Voltage and Current Harmonics: 2nd to 50th harmonic
– Voltage and Current Unbalance measurement
– Captures voltage dips, swells and interruptions
– Captures inrush current events
– 16-bit synchronous sampling
– Sampling Frequency: 10.24 kHz at 50/60 Hz
– Selectable logging intervals from 1 second to 30 minutes
– Internal flash memory for long-term logging
– Supports single-phase, split-phase and three-phase systems
– 4.3-inch Color TFT Touchscreen
– Display Resolution: 480 × 272 pixels
– Fluke Connect® compatible
– Wi-Fi connectivity for file transfer and remote control
– USB connectivity for data transfer
– Compatible with Fluke Energy Analyze Plus software
– Can be powered directly from the measured circuit
– Rechargeable Li-ion battery
– Battery Runtime: approximately 4 hours in standard mode and up to 5.5 hours in power-saving mode
– Protection Rating: IP50
– Safety Rating: CAT III 1000 V / CAT IV 600 V
– Operating Temperature: -10°C to +50°C
– Dimensions: 19.8 × 16.7 × 5.5 cm
– Weight: approximately 1.1 kg

Applications:

– Three-Phase Power Monitoring
– Energy Consumption Studies
– Load Studies
– Basic Power Quality Analysis
– Harmonic Analysis
– Voltage and Current Monitoring
– Power Factor Analysis
– Electrical System Troubleshooting
– Energy Audits
– Preventive and Predictive Maintenance

Reviews

There are no reviews yet.

Be the first to review “Fluke 1736 Three-Phase Power Logger with Fluke Connect”
Fluke 1736 Three-Phase Power Logger with Fluke Connect
Fluke 1736 Three-Phase Power Logger with Fluke Connect EGP 521,000.000
In Stock