No products in the cart.
Very useful for power distribution companies, power utilities and maintenance fields
| AC A | 0 – 600.0/1000A ±2.0%rdg±5dgt (50/60Hz) ±3.5%rdg±5dgt (40 – 500Hz) |
| DC A | 0 – 600.0/1000A ±1.5%rdg±5dgt |
| AC V | 6/60/600V(Auto-ranging) ±1.5%rdg±4dgt (50/60Hz) ±3.5%rdg±5dgt (40 – 400Hz) |
| DC V | 600mV/6/60/600V(Auto-ranging) ±1.0%rdg±3dgt |
| Ω | 600Ω/6/60/600kΩ/6/60MΩ (Auto-ranging) ±1%rdg±5dgt (600 – 6M) ±5%rdg±8dgt (60M) |
| Continuity buzzer | Buzzer Sounds at 100Ω |
| Capacitance test | 400nF/4/40μF(Auto-ranging) |
| Temperature | -50 – +300ºC (With the use of Temperature probe 8216) |
| Frequency | 10/100Hz/1/10kHz(Auto-ranging) |
| DUTY | 0.1 – 99.9% |
| Conductor size | Ø40mm |
| Safety Standard | IEC 61010-1 CAT IV 600V, IEC 61010-031 IEC 61010-2-032, IEC 61326 |
| Power source | R03 (1.5V) (AAA) × 2 |
| Dimension | 254(L) × 82(W) × 36(D)mm |
| Weight | Approx. 310g |
| Accessories | 7066A (Test leads) 9094 (Carrying case) Instruction Manual |
| Optional Accessories | 8216 (Temperature probe) |